Primary Application
Fresh or frozen unpackaged meat products separated or bulk, or packed in crates and cartons
-
Contamination Detection
Metal, glass, stone, bone, high-density plastics, rubber, low-density contaminants
-
Quality/Integrity Inspection
Missing item, clip, count, void, broken-item, mass, sorting, shape, package integrity
-
Compliance/Validation/ Reporting
User management, guided performance verification routine (PVR), machine health checks, reject bin
monitoring, PDF reports, risk-assessment support
-
Lane Configuration
Single or multi-lane system
-
Conveyor Speed
Up to 55 m/min (180 ft/min); conveyor speed ranges are determined by the selected motor
-
Throughput
Up to 31.8 tonnes/hr (35.1 tons/hr); up to 2,400 crates/hr
-
Maximum Product Height
Up to 229 mm (9”); see beam geometry limits
-
Detector Technology
0.1–0.8 mm PXT™ photon-counting detector options; 0.4 mm standard or 1.2 mm dual energy
-
X-ray Generator
HR7, up to 140 kV, up to 1 mA glass tube; HR9N, up to 140 kV, up to 3 mA glass tube
-
HMI
15.6” PCAP touchscreen, Full-HD (1920 × 1080), 250 GB memory
-
Operating System
Windows 11 LTSC
-
Inspection Software
SimulTask™ 6
-
Traceability/Reporting/ Connectivity
Eagle Repository™, TraceServer™, PDF reporting, centralized storage, OPC-UA, Ethernet/IP
-
Safety Features
Up to Category 3 / PLd (EN13849) safety circuit with HMI visibility, LOTO disconnect, compliant to 21 CFR 1020.40, 21 CFR 179.21; <1 μS/hr emissions
-
Ingress Protection/Hygienic Features
IP69; type 304 stainless steel; surface finish less than 0.8μm/32μ-inch RA (ISO 21920-3); designed to NAMI Sanitary Guidelines, EHEDG, NSF, ISO, and CE standards where feasible
-
Operating Environment
0–40°C (32–104°F); 25–90% RH non-condensing
-
Power Supply
230 VAC ±10%, single phase, 50/60 Hz, FLA 9.0A
-
Cooling
8k BTU shrouded AC (IP69)
-
Compressed Air
Not required for base machine; rejects may require 5.5 bar (80 psi), 3/8” line; dry and filtered air supply
-
External Interface
(8) rejects, (5) inputs, (9) outputs, and (4) PLC monitoring signals for: system processing, system calibrating, fault condition, x-rays on
-
Reject Options
24 VDC signal, free-standing push-arm reject conveyor; reject verification sensors available
-
Remote Service
TeamViewer™ or customer-specific solution for remote service, diagnostics, and product set-up assistance; 24-hr support
-
Conveyor Length
2,284 mm (90”)
-
Conveyor Height
850–1,400 mm (33.5–55.1”); additional heights upon request
-
Inspection Area at Belt
433 mm (17”)